Lighting and socket management

This section describes the functions for controlling connected lighting fixtures and sockets.

They allow you to control switching on, switching off and dimming of lighting equipment, as well as turning on or off any device plugged into a connected socket.

Output types

Driving a light fixture or a socket goes through a power output whose type depends on the product. That type decides which load can be connected to the output and which wiring is possible: it is the first criterion to identify.

  • Dry-contact relay output — drives equipment through a potential-free contact.

  • Power relay output — directly switches a load on the mains network (lighting, sockets).

  • MOS dimmer output — one and the same output provides both On/Off control and dimming. It requires a prior calibration (Dimmer output calibration), and it is the only one whose load is constrained: see Loads supported on a dimmer output.

The output type determines the product’s power electronics, but the functional On/Off behaviour is identical whatever the output type.

Only a MOS dimmer output accepts no neutral (2-wire) wiring. Products with a relay output are wired with neutral (3-wire) only.

📋 Requirement: no-neutral (2-wire) wiring requires a MOS dimmer output. A relay output, dry contact as well as power, is wired with neutral (3-wire).

📋 Requirement: the functional On/Off behaviour is the same whatever the output type.

Loads supported on a dimmer output

This chapter only applies to products whose output is a MOS dimmer, in On/Off control as well as in dimming. A product has a dimmer output as soon as it offers the Dimming function or no neutral (2-wire) wiring — see Output types. Products with a relay output drive any lamp, with no calibration and no compatibility constraint.

The load that can be driven then depends on two criteria, which must not be confused: the product wiring (no neutral, 2-wire, or with neutral, 3-wire) and the requested function (On/Off or dimming).

This chapter covers the lamp type. Power limits are specific to each product and appear on its page, in the maximum admissible load table.

Wiring

Lamp type

On/Off control

Dimming

No neutral (2-wire)

On/Off (non-dimmable)

Not supported

Not supported

No neutral (2-wire)

Dimmable

Most tested lamps

Yes, manual adjustment of the low threshold sometimes required

With neutral (3-wire)

On/Off (non-dimmable)

Vast majority of tested lamps

Not applicable

With neutral (3-wire)

Dimmable

All tested lamps

All tested lamps, manual adjustment of the low threshold sometimes required

Warning

With no-neutral wiring (2-wire), a dimmable lamp is mandatory, including for On/Off control alone: no standard On/Off LED lamp can be driven. When replacing a non-connected switch without neutral by a connected switch, the existing lamps must therefore be replaced if they are not dimmable.

Note

A lamp declared compatible is compatible in every tested situation — a single lamp and several units of the same reference. Driving a single lamp is generally harder than driving several lamps of the same reference; the opposite is observed in rare cases.

Compatibility does not rule out flicker with the default thresholds: see Dimmer output calibration.

📋 Requirement: with no-neutral (2-wire) wiring, control requires a dimmable lamp, for On/Off control as well as for dimming.

📋 Requirement: a relay output drives any lamp, with no calibration and no type constraint.

📋 Requirement: a lamp declared compatible is compatible as a single unit as well as with several units of the same reference.

Dimmer output calibration

La calibration remplit plusieurs objectifs essentiels :

  • Identifier si le produit est câblé avec ou sans Neutre.

    • Avec Neutre, le produit utilise les fonctions de :

      • Détection de coupure du secteur

      • Détection de charge nulle

  • Déterminer le rapport cyclique maximal nécessaire pour les fonctionnalités suivantes :

    • Afin de gérer le mode capacitif/inductif

    • En câblage sans Neutre avec variation, la calibration garantit l’alimentation du produit en fonction de la charge :

      • Le produit doit garder suffisamment de tension pour son propre fonctionnement.

    • Maintenir un rapport cyclique suffisant pour alimenter le produit tout en cadrant ce rapport avec des limites minimales et maximales adaptées à différents types d’ampoules :

      • En dessous du minimum, aucune lumière n’est émise par l’ampoule.

      • Le minimum permet de gérer le scintillement aux premières lueurs.

    • À 85 %, le rapport cyclique permet d’avoir une mesure de puissance active fiable en mesurant le déphasage tension/courant. Si le rapport cyclique est de 100 %, la mesure du déphasage n’est plus possible et la mesure sera la mesure de la puissance réactive.

Calibration automatique

Cette calibration se déclenche automatiquement :

  • Lors de l’activation de la fonctionnalité.

  • À chaque mise sous tension du produit.

    • Elle a donc lieu après chaque coupure de courant du produit connecté, et non à chaque extinction de l’ampoule : dans ce dernier cas le produit reste alimenté.

    • Après un redémarrage, la calibration permet de vérifier si le câblage du produit et/ou la charge ont été modifiés.

La calibration peut prendre plusieurs dizaines de secondes, jusqu’à 1 minute.

À la fin de cette calibration :

  • Le rapport cyclique minimal est fixé à 25 %. Il ne peut pas être déterminé automatiquement par le produit : cette valeur est fixée par défaut.

  • Le rapport cyclique maximal dépend de la charge et est limité à 85 % maximum. C’est le rapport cyclique le plus élevé auquel la charge reste suffisamment stable pour que le produit fonctionne normalement.

Important

Ces deux seuils sont déterminés sur des critères fonctionnels. Ils ne traitent pas le scintillement, qui peut apparaître à l’intérieur de la plage retenue et demande alors un ajustement manuel du seuil bas par l’utilisateur.

Calibration utilisateur

Cette calibration, sélectionnable depuis l’application, permet à l’utilisateur d’ajuster le rapport cyclique en fonction de la charge. C’est par elle que se corrige un scintillement subsistant dans la plage déterminée automatiquement.

📋 Requirement: automatic calibration runs when the feature is activated and every time the product is powered up.

📋 Requirement: calibration determines whether the product is wired with or without neutral.

📋 Requirement: calibration completes within 1 minute.

📋 Requirement: user calibration, started from the application, adjusts the duty cycle to the load and corrects flicker remaining within the automatically determined range.

On/Off control

On/Off control lets you switch a light on and off, or turn an electrical device such as a connected socket on and off.

The principle relies on associating a command feature (transmitter) with a control feature (receiver). The command sends an On or Off order over the Bluetooth Mesh network, and the controller executes it by driving its output.

Command sources

An On/Off control feature can be driven by different sources:

  • The mobile app, either locally (Bluetooth) or remotely (via a WiFi gateway),

  • A physical switch (push-button, two-way) bound over the Mesh network,

  • A motion detector bound to the controller,

  • A scenario configured from the app,

  • A voice assistant (via the gateway and the Cloud),

  • The IoT Hub (restricted access, administration)

Driven output

The On/Off controller drives the product’s power output, whatever its type — see Output types.

On a MOS dimmer output, each On command drives the output to the maximum duty cycle determined by the calibration, not to 100%. On/Off control there therefore requires a lamp that supports dimming: see Loads supported on a dimmer output.

Type of appliance driven by the output

When the product is installed, the application lets you choose — depending on the product — the type of appliance the output drives:

  • On/Off lamp

  • Socket

This choice is not cosmetic: it decides the output state after a power cut and whether the end-of-timer alert applies — see On/Off “socket” output and On/Off timer.

On/Off switch

There are different types of switches to control On/Off outputs:

  • two-way switch

  • push-button

On/Off “light” output

Attention

Chapter not yet documented.

On/Off “socket” output

Default behaviour

The state taken by the output depends on the appliance type chosen at installation, and on the situation considered.

📋 Requirement: when the feature is activated, by binding from the application, the output takes the On state in On/Off Light mode, and Off in Socket mode.

📋 Requirement: when power is restored after an outage, the output takes the On state in On/Off Light mode, and Off in Socket mode.

📋 Requirement: after a software update, the output takes the On state in On/Off Light mode, and Off in Socket mode.

📋 Requirement: on uninstallation as on Factory Reset, the output takes the Off state, whatever the appliance type.

Why Lamp = On and Socket = Off

The two states retained after a power cut are not symmetrical, for distinct reasons:

  • Lamp On — lets you get the light back after an outage, typically during a storm.

  • Socket Off — avoids restarting a heavy load left switched on, such as a water heater or a radiator. Several loads restarting at once may trip the meter, and the load would restart outside the intended hours (peak hours, red Tempo day).

On/Off timer

Activation

The output can be set to a timer (from 1 min to 20h).

Activation and the time setting are done in the product page’s settings menu.

End-of-timer alert

For lighting functions only: when the timer is active, the light briefly flashes once, 5 seconds before the timer ends, to warn the user.

📋 Requirement: the timer is set from 1 minute to 20 hours, from the settings menu of the product page.

📋 Requirement: when the timer expires, the output goes to the Off state.

📋 Requirement: 5 seconds before the timer ends, the output briefly flashes once. The alert applies in On/Off Light mode only.

Dimming control

Dans le cadre de la gestion et du contrôle des systèmes d’éclairage, la fonction “variation” joue un rôle essentiel en permettant de piloter les lampes à des intensités lumineuses différentes.

Cette fonctionnalité offre une flexibilité accrue pour ajuster l’éclairage en fonction des besoins spécifiques, qu’il s’agisse de créer une ambiance particulière, d’optimiser la consommation énergétique ou de répondre à des exigences techniques précises.

En modulant l’intensité lumineuse des lampes, la fonction “variation” contribue à améliorer le confort visuel tout en favorisant une utilisation plus rationnelle des ressources électriques.

Dimmer push-button

Un bouton poussoir peut être associé à une sortie Variation.

Le bouton poussoir permet de contrôler l’intensité lumineuse d’un luminaire de manière intuitive, par des appuis courts et longs.

Gestes et comportements

Geste

Ce qui se passe

Appui court

Allume le luminaire au dernier niveau de luminosité utilisé, ou l’éteint s’il est déjà allumé.

Appui long (maintenu)

Fait varier progressivement l’intensité — vers le haut ou vers le bas — tant que le bouton reste enfoncé.

Relâchement (après un appui long)

La luminosité se fige au niveau atteint à l’instant où le bouton est relâché.

Fin de temporisation

Si une temporisation est configurée, le luminaire s’éteint progressivement sur 5 secondes (effet de fondu).

Tip

  • Le niveau de luminosité est mémorisé : lorsque vous rallumez le luminaire par un appui court, il retrouve automatiquement le dernier réglage utilisé.

  • Alerte visuelle avant extinction : si une temporisation est active, l’intensité diminue doucement pendant les 5 dernières secondes pour vous prévenir de l’extinction imminente. Un simple appui court permet de relancer l’éclairage.

📋 Requirement: a short press switches the output on at the last brightness level used, or switches it off if it is already on.

📋 Requirement: a long press varies the intensity as long as the button is held down.

📋 Requirement: when the button is released, the intensity freezes at the level reached.

Dimming output

The dimming output requires a dimmable LED lamp, with or without neutral. The wiring / lamp type matrix is given in Loads supported on a dimmer output.

Dimming takes place between the low and high thresholds determined by the calibration — see Dimmer output calibration. These thresholds are determined on functional criteria: they do not address flicker, which may appear within the retained range and then requires the user to adjust the low threshold manually.

The edge control type is Leading by default. The user can switch it to Trailing from the mobile application when the load requires it.

📋 Requirement: the dimming output requires a dimmable LED lamp, with neutral as well as without neutral wiring.

📋 Requirement: dimming takes place between the low and high thresholds determined by the calibration.

📋 Requirement: the edge control type is Leading by default, and is switched to Trailing from the mobile application.

Color lighting control (RGB/RGBW)

Attention

Function not currently available.

Dimming timer

Activation

La sortie peut être temporisée (de 1 min à 20h).

L’activation et le choix du temps se font dans le menu réglages de la page produit.

Alerte de fin de temporisation

Lorsqu’une temporisation est active sur la fonctionnalité, une alerte de fin de temporisation prévient l’utilisateur que la lumière va s’éteindre avec la baisse progressive de l’intensité lumineuse (fading) sur les 5 dernières secondes avant la fin de la temporisation.

📋 Requirement: the timer is set from 1 minute to 20 hours, from the settings menu of the product page.

📋 Requirement: the intensity decreases gradually over the 5 seconds before the timer ends.

Motion detection

La fonction Détection de mouvement permet de détecter automatiquement une présence dans une pièce grâce à un capteur infrarouge passif (PIR). Lorsqu’un mouvement est détecté, le produit déclenche automatiquement une action sur les équipements associés (éclairage, prise, variateur…) via le réseau Bluetooth Mesh.

Produits compatibles

La détection de mouvement est disponible sur (voir Produits concernés) :

  • Micromodules — via une entrée filaire (Line Input) raccordée à un capteur externe

  • Détecteurs autonomes — produits dédiés

Cas d’usage

Lorsqu’un mouvement est détecté, le détecteur peut :

  • Allumer un éclairage (via un contrôleur On/Off) avec une temporisation paramétrable

  • Activer un variateur (via un contrôleur Variation) au dernier niveau de luminosité utilisé, avec temporisation

  • Déclencher un scénario (ex : allumage de plusieurs pièces simultanément)

  • Envoyer une alerte “Maison vigilante” lorsque le mode surveillance est activé

  • Remonter l’événement vers le cloud pour notification ou historique (si une passerelle est présente)

Configuration depuis l’application mobile

  1. Choix du template : Sélectionnez « Détecteur de mouvement » comme template d’entrée lors de la configuration du produit.

  2. Association aux récepteurs : Choisissez un ou plusieurs équipements à piloter (lampes, prises, variateurs). Par défaut, une temporisation de 10 minutes est appliquée sur chaque récepteur associé.

  3. Réglage de la temporisation : Modifiable depuis la page du contrôleur associé.

  4. Seuil jour/nuit (REF30, REF31, REF32 uniquement) : Permet de ne déclencher l’action que lorsque la luminosité ambiante est inférieure à un seuil configurable (mode « Ne déclencher que la nuit »).

Comportement

  • À la détection d’un mouvement, le détecteur publie son état de détection. Les fonctionnalités de contrôle associées s’activent pour la durée de leur temporisation. Le détecteur ne décide pas de l’action : il signale la détection, c’est le récepteur qui l’interprète.

  • Si le mouvement persiste, la détection est republiée toutes les 30 secondes, et chaque publication relance la temporisation côté récepteur.

  • À la fin de la temporisation (sans nouvelle détection), le récepteur s’éteint automatiquement.

  • L’état imposé au récepteur dépend de sa nature : une sortie On/Off passe à On, une sortie variation reprend le dernier niveau non nul si elle était éteinte.

  • Si la temporisation est désactivée sur un récepteur associé, un bandeau d’avertissement s’affiche : « Vous avez associé ce produit à un détecteur de mouvement. Vous devriez paramétrer une temporisation. »

Mode « Ne déclencher que la nuit »

Disponible sur les détecteurs autonomes (REF30, REF31, REF32), qui mesurent la luminosité ambiante.

  • La luminosité est mesurée au moment de la détection, et à chaque retour au repos du capteur : aucune mesure périodique n’est faite.

  • Selon que la mesure dépasse le seuil ou non, la détection est qualifiée de jour ou de nuit. Les fonctionnalités de contrôle ne réagissent qu’aux détections de nuit ; quand le mode est inactif, toutes les détections sont qualifiées de nuit, donc toutes déclenchent.

  • L’alerte Maison vigilante se déclenche de jour comme de nuit, indépendamment du mode.

  • L’application propose quatre seuils : 1 lux (nuit noire), 10 lux (pénombre), 100 lux (crépuscule) et 1000 lux (à l’ombre en journée).

  • Sur REF32, qui est un Low Power Node, l’application demande le réveil du produit avant d’écrire le réglage.

📋 Requirement: on motion detection, the detector publishes its detection state on the mesh network. The bound control features activate for the duration of their timer.

📋 Requirement: on detection, a bound On/Off output goes to On, and a bound dimming output resumes the last non-zero level if it was off.

📋 Requirement: when bound from the application, each receiver gets a 10-minute timer.

📋 Requirement: when the “trigger at night only” mode is active, the bound control features react to detections qualified as night only. When it is inactive, every detection triggers.

📋 Requirement: the application offers four day/night qualification thresholds: 1, 10, 100 and 1000 lux.

📋 Requirement: the Vigilant Home alert triggers by day as well as by night, whatever the state of the “trigger at night only” mode.